If you are remodeling or having a new construction built in Denver, then it is very important that you are aware of the egress window building codes in effect in Denver, Colorado. Now of course, if you are using a reputable builder and a good window company like Wholesale Home Improvements then the expert workmen will already be up to speed on what is necessary for your area. But it is always a good idea to educate yourself a little and have at least of an idea of what should be happening, making you more aware if your builder tries to cut corners that shouldn’t be cut to underbid another contractor, etc. In today’s competitive and fast-paced environment you cannot be too careful about that kind of thing.

egress2First things first one, of the most basic and obvious requirements is that every sleeping room below the fourth floor and that includes basements must have at least one window or door. That window or door must be able to be opened from the inside without the use of a special, separate tool. The opening should be big enough for a person to easy fit through and the opening should be kept clear at all times. Plus, the window or door should open to a street, yard, alley, exit court or otherwise open area where escape is possible.

Windows that are specifically enlisted to serve as escape or rescue windows must meet minimum size requirements. First off, the window should open so that the opening measures at least 5.7 square feet with a minimum height requirement of 24 inches and a minimum width of 20 inches. Plus, the window sill should not be more than 44 inches from the floor to allow for easier accessibility.

basement4In cases where the sill height of the window ends up being below the adjacent ground elevation, a window well is required to meet the egress window building codes in Denver, Colorado. The well must have a minimum clearance of 9 square feet with no single dimension being less than 36 inches. If the well has a vertical depth of more than 44 inches, then a permanently installed ladder or stairs must be available and not encroach on the minimum space requirements for the window well by any more than 6 inches.

If you wish to install bars, grilles, grates, or anything else similar, you are permitted, but the structure must remove easily from the inside with no need for special knowledge or separate tools, and the release mechanism must be inspected and approved. Plus, the building must have smoke detectors correctly installed according to Denver’s smoke detector regulations.

So there you have it! Egress window building codes in Denver Colorado are not too difficult to understand and comply with easily. Much of it is just common sense. But, of course, compliance is extremely important as one day your life, or the life of a loved one, just may depend on it.